European XFEL: Superconducting undulator modules for an afterburner for SASE2 - FESTA

European X-Ray Free-Electron Laser Facility GmbH

Deutschland

07.12.2026

Beschreibung

Scope of Work After Award: The tender covers the following components and requirements: Superconducting Undulator Modules: Composition: Small series of five with an option of sixth SCU module, each approximately 5 meters long. Installation: The SCU modules will be positioned after the existing 35 permanent magnet undulator modules of the SASE2 line at European XFEL Technical design report: A Technical Design Report (TDR) for one representative SCU module must be provided after award to EuXFEL for review and approval Tests: An intermediate test of all the SCU magnets in a liquid-helium (LHe) vertical cryostat at DESY (SUNDAE1), carried out under the responsibility of EuXFEL, is foreseen to train and characterize the magnetic field. The acceptance tests of each SCU module include: factory acceptance test (FAT) and three site acceptance tests: the first SAT which includes magnetic characterization, SAT2 in the tunnel without beam and SAT3 in tunnel with beam. Timeline: The fifth SCU module must be delivered latest by June 2032, and the sixth optional SCU module, if the option is exercised, latest by June 2033. Technical Specifications include: Magnetic Configuration: Each SCU module consists of two 2 m long SCU magnets, each with: Vacuum stay-clear: 5 mm Period: 18 mm Peak magnetic field: ≥ 1.82 T The root mean square of the relative variation of the undulator parameter defined over half period must be smaller than 0.004 The range of the relative variation of the undulator parameter defined over half period must be smaller than 0.012 Shimming coils must be applied in case the undulator parameters mentioned above are not reached in the measurement in SUNDAE1: root mean square of the relative variation of the undulator parameter defined over half period larger than 0.004 and /or the range of the relative variation of the undulator parameter defined over half period larger than 0.012. Components: - A cryostat for thermal isolation consisting of a vessel and several thermal shields. - An electron beam vacuum chamber (EBC) with the following functions: separating the isolation vacuum, where the superconducting magnets are located, from the ultra high vacuum where the electron beam moves, shielding the superconducting magnets from beam heat load. - Two SCU magnets, each consisting of a top and bottom coil held together by a support structure, equipped with correction coils. - Horizontal and vertical Helmholtz coils at the exit of the upstream SCU magnet and at the entrance of the downstream SCU magnet. - A phase shifter to manage phase mismatch between the two SCU magnets. A support structure holding together the Helmholtz coils and the phase shifter. This support structure and the ones of the SCU magnets must keep the superconducting magnets at the final gap and have to be designed and manufactured to fit in the magnetic gap precisely machined rails to guide a sledge with Hall probes. The sledge with Hall probes will be provided by EuXFEL. This is needed to perform the test in SUNDAE1 mentioned above. The contract will provide for a firm obligation to supply five (5) SCU modules. In addition, the contract will include an option entitling EuXFEL, at its sole discretion, to order one (1) additional (sixth) SCU module with the same technical specifications and on the same contractual terms. The option shall lapse if EuXFEL does not exercise it by the end of July 2029. EuXFEL is under no obligation to exercise the option. Further details will be set out in the procurement documents, including the complete technical specification, which will be provided to the selected candidates following completion of the selection stage and submission of the confidentiality agreement.

Der Datensatz

Wie veröffentlicht. Der Bekanntmachungstext bleibt beim Herausgeber.

Auftraggeber

European X-Ray Free-Electron Laser Facility GmbH

Land

Deutschland

Regionen (NUTS)

Hamburg

Kategorie

Laborgeräte, optische Geräte und Präzisionsgeräte (außer Gläser) · Laboratory, optical and precision equipment38000000

Frist

07.12.2026

Veröffentlicht

09.11.2026

Sprachen

Deutsch (German)

Quelle

TED (EU) · 778066-2026

So bieten Sie

Verfahren

Verhandlungsverfahren mit Teilnahmewettbewerb

Angebot einreichen unter

https://www.subreport.de/E63916373

Sprache der Einreichung

ENG

Elektronische Einreichung

Erforderlich

Vergabeunterlagen

Frei zugänglich

Vertragsbedingungen

Auftragsart

Lieferungen

Erfüllungsort

DE600

Rahmenvereinbarung

Nein

Dynamisches Beschaffungssystem

Nein

Nebenangebote

Zugelassen

EU-gefördert

Nein

Rechtsgrundlage

32014L0024

Auftraggeber kontaktieren

E-Mail

tender@xfel.eu

Telefon

+49 40 8998 6006

Anschrift

Holzkoppel 4, 22869, Schenefeld

Website

https://www.xfel.eu

Kann Ihr Unternehmen darauf bieten?

Website einfügen. Wir lesen, was das Unternehmen macht, und bewerten es gegen diese Ausschreibung. Kein Konto.

Offene Ausschreibungen wie diese

Sortiert danach, worum es in den Bekanntmachungen geht, nicht nach passenden Wörtern im Titel.

Die Bekanntmachungsdaten stammen aus offiziellen Quellen: Tenders Electronic Daily (TED), herausgegeben vom Amt für Veröffentlichungen der Europäischen Union nach dem Beschluss 2011/833/EU der Kommission; oeffentlichevergabe.de und TenderNed, veröffentlicht unter CC0; BOAMP, veröffentlicht unter der Licence Ouverte 2.0; Find a Tender, veröffentlicht unter der Open Government Licence v3; sowie e-Zamówienia, die Plataforma de Contratación del Sector Público und die von der ANAC herausgegebene Piattaforma di Pubblicità a Valore Legale sowie Doffin und Hilma, veröffentlicht von den jeweiligen nationalen Behörden. Jede Bekanntmachung führt zum Original, und das Original ist maßgeblich.

Nur die sehen, die zu Ihrem Unternehmen passen

Ausschreibungen wie diese erscheinen jede Woche. Mit einem Profil sehen Sie die, die Ihr Unternehmen gewinnen kann, bewertet und mit einer Zeile, die jeden Treffer erklärt.

Kostenlos starten